Wednesday, September 21, 2016

Example: MDS Zoning

on BTP-MDS03 SWITCH (HBA1), zone the following for BTP Prod Pure Array #2








zone name btpesxu4c3b4-BTP-PURE02-VDI-CT0FC1 vsan 1
  member device-alias BTP-VDI-CT0FC1
  member device-alias btpesxu4c3b4

zone name btpesxu4c3b4-BTP-PURE02-VDI-CT0FC3 vsan 1
  member device-alias BTP-BTP-VDI-CT0FC3
  member device-alias btpesxu4c3b4

zone name btpesxu4c3b4-BTP-PURE02-VDI-CT1FC1 vsan 1
  member device-alias BTP-PURE02-VDI-CT1FC1
  member device-alias btpesxu4c3b4

zone name btpesxu4c3b4-BTP-PURE02-VDI-CT1FC3 vsan 1
  member device-alias BTP-PURE02-VDI-CT1FC3
  member device-alias btpesxu4c3b4

zoneset name Production_Zoneset_A vsan 1
  member btpesxu4c3b4-BTP-PURE02-VDI-CT0FC1
  member btpesxu4c3b4-BTP-PURE02-VDI-CT0FC3
  member btpesxu4c3b4-BTP-PURE02-VDI-CT1FC1
  member btpesxu4c3b4-BTP-PURE02-VDI-CT1FC3

zoneset activate Production_Zoneset_A vsan 1



on BTP-MDS04 SWITCH (HBA2), zone the following for BTP Prod Pure Array #2


config t

zone name btpesxu4c3b4-BTP-PURE02-VDI-CT0FC0 vsan 1
  member device-alias BTP-PURE02-VDI-CT0FC0
  member device-alias btpesxu4c3b4

zone name btpesxu4c3b4-BTP-PURE02-VDI-CT0FC2 vsan 1
  member device-aliasBTP-PURE02-VDI-CT0FC2
  member device-alias btpesxu4c3b4

zone name btpesxu4c3b4-BTP-PURE02-VDI-CT1FC0 vsan 1
  member device-alias BTP-PURE02-VDI-CT1FC0
  member device-alias btpesxu4c3b4

zone name btpesxu4c3b4-BTP-PURE02-VDI-CT1FC2 vsan 1
  member device-alias BTP-PURE02-VDI-CT1FC2
  member device-alias btpesxu4c3b4

zoneset name Production_Zoneset_B vsan 1
  member btpesxu4c3b4-BTP-PURE02-VDI-CT0FC0
  member btpesxu4c3b4-BTP-PURE02-VDI-CT0FC2
  member btpesxu4c3b4-BTP-PURE02-VDI-CT1FC0
  member btpesxu4c3b4-BTP-PURE02-VDI-CT1FC2

zoneset activate Production_Zoneset_B vsan 1